Rinse Tank Timer model T2 has a 15A relay output. Two time cycles are independently settable. Each can range from 1 second to 99 minutes.
Typical Operation At the end of the first time cycle, when a load should be removed from a rinse tank for example, the illuminated push button flashes and the audio buzzer sounds. When the button is pushed to silence the alarm, the second time cycle from 1sec-99min starts. The second time cycle can open a solenoid valve to control rinse water flow. When the second time cycle is complete, the buzzer sounds briefly.
Alternate Operation Mode The first time cycle could be used to prepare the tank by turning on a heater to warm it up, or to dose chemicals by turning on a pump. When the first time cycle has elapsed and the rinse is prepared, the buzzer sounds until acknowledged. This is a cue to run work thourgh the tank. At the end of the second time cycle the buzzer sounds again.
|